Circulation Heater Options


TERMINAL HOUSINGS

Screw Plug
NEMA 4/7 Moisture/Explosion Resistant
Suction Oil Heaters
Plug Size
C
D
E
F
G
1"
3 516
 
4 ½
1
6 ⅛
1 ¼ NPT
2" & 2 ½"
4 ⅜
5 ¾
1 ¼
7 ⅝
1 ½ NPT


 

Flanged
 
NEMA 4 Moisture Resistant
 
Circulation Heater Option - Flanged NEMA4
 
Flange Size
"A" Maximum
3" - 150#
4 ½"
5" - 150#
6 ¾"
8" - 150#
8 ¾"
10" - 150#
10 ¾"
12" - 150#
12 ¾"
14" - 150#
14 ¾"
Flanged
 
NEMA 7 Moisture Resistant
 
Circulation Heater Option - Flanged NEMA4
 
Flange Size
"A" Maximum
3" - 150#
4 ½"
5" - 150#
6 ¾"
8" - 150#
8 ¾"
10" - 150#
10 ¾"
12" - 150#
12 ¾"
14" - 150#
14 ¾"

TEMPERATURE CONTROLS

Bulb & Capillary
 
 
 
Style
Range
Code No.
Availability
Single Pole
 
 
30-110°F
T1
All 1" Screw Plugs
60-250°F
T2
Std. on 1" Plugs
175-550°F
T3
All 1" Screw Plugs
Double Pole
 
 
0-100°F
T4
All Plugs & Flanges
60-250°F
T5
Std. on 3", 5", 8" Flange
150-500°F
T6
All Plugs & Flanges


 

Solid State
 
 
 
Style
Range
Code No.
Availability
Non-Indicating Sub-Panel
 
 
0-300°F
86-03
All Plugs & Flanges
0-800°F
86-08
All Plugs & Flanges
500-1500°F
86-515
All Plugs & Flanges
¼ DIN Deviation Meter
 
 
0-300°F
20-03
All Plugs & Flanges
0-800°F
20-08
All Plugs & Flanges
500-1500°F
20-515
All Plugs & Flanges
¼ DIN Digital LED
0-1000°F
40-01
Std on High Capacity
Avail. on all others
0-2000°F
40-02
All Plugs & Flanges

OTHER OPTIONS

High Temp. Standoff Housing
Conduit Connections - Circulation Heaters


 

Over Temp. Thermocouple to Sheath
Over Temp. Thermocouple to Sheath  - Circulation Heaters
(Standard on High Capacity Heaters)


 

Additional Options
 
a.
Weatherproof insulation shroud
b.
High temp. ceramic fiber insulation. (Standard on high capacity units.)
c.
All stainless steel construction.
d.
Passivation on all wetted surfaces
e.
ASME section 8 construction on vessel
f.
High pressure construction

Certifications

Our heaters are currently UL recognized, CSA compliant and CE approved. We are ASME and National Board certified for Section VIII Div 1 Pressure Vessel Welding.

Additionally, we have built heaters to Military standards for the Army, Navy, Coast Guard and DCSC. We have designed and built systems to Canadian pressure vessel codes CRN, ABSA & TSSA. We also meet certain NSF, NACE and API standards.

A.S.M.E SECTION VIII, DIVISION 1 CERTIFIED
A.S.M.E SECTION VIII, DIVISION 1 CERTIFIED
C.S.A CERTIFIDIED FILE #LR61119
Registered Firm Mark UL RECOGNIZED FILE #L130401
Registered Firm Mark UL RECOGNIZED FILE #L130401
CE CERTIFIED