Monday, February 06, 2012
   
TEXT_SIZE

3", 5" & 8" - 150# Flanged Circulation Heaters

Flange Size
D
E
F
G
H
J
K
M
3"150#
8 ¾"
9"
6"
1" NPT
⅜ - 16
1¼"
6"
3 ½"
5"150#
10 ½"
10 ¾"
8"
2" NPT
⅜ - 16
1 ¼"
7"
5"
8"150#
12"
12 ¼"
10"
2 ½" NPT
⅜ - 10
3 ½"
8"
5"

2 and 2.5 inch NPT screw plug circulation heater

 
3" - 150#
48 Watts per sq. inch - Water & Mild Solutions
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
6
C3H3-60-3T5
C3H3-60-5T5
33
22 ½
16 ½
70
240
480
7.5
C3H3-75-3T5
C3H3-75-5T5
33
22 ½
16 ½
70
240
480
9
C3H3-90-3T5
C3H3-90-5T5
33
22 ½
16 ½
70
240
480
12
C3H3-120-3T5
C3H3-120-5T5
43 ¼
32 ½
26 ½
80
240
480
15
C3H3-150-3T5
C3H3-150-5T5
55 ¾
45
39
96
240
480
18
C3H3-180-3T5
C3H3-180-5T5
55 ¾
45
39
98
 
3" - 150#
23 Watts per sq. inch - Light wt. oils, caustics, air, gases & mild corrosives
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
3
C3M3-30-3T5
C3M3-30-5T5
33
22 ½
16 ½
70
240
480
4.5
C3M3-45-3T5
C3M3-45-5T5
33
22 ½
16 ½
70
240
480
6
C3M3-60-3T5
C3M3-60-5T5
43 ¼
32 ½
26 ½
80
240
480
7.5
C3M3-75-3T5
C3M3-75-5T5
55 ¾
45
39
96
240
480
9
C3M3-90-3T5
C3M3-90-5T5
55 ¾
45
39
98
240
480
12.5
C3M3-125-3T5
C3M3-125-5T5
73 ¾
63
53
120
 
3" - 150#
13 Watts per sq. inch - Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
3
C3L3-30-3T5
C3L3-30-5T5
43 ¼
32 ½
26 ½
80
240
480
3.75
C3L3-37-3T5
C3L3-37-5T5
51 ¾
41
26 ½
92
240
480
5
C3L3-50-3T5
C3L3-50-5T5
61 ¾
51
26 ½
100
240
480
6.25
C3L3-62-3T5
C3L3-62-5T5
73 ¾
63
26 ½
120
240
480
7.5
C3L3-75-3T5
C3L3-75-5T5
85 ⅝
74 ⅞
26 ½
140
 
3" - 150#
8 Watts per sq. inch - Heavy oils, #6 & Bunker C fuel oils, corrosive, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
2
C3V3-20-3T5
C3V3-20-5T5
43 ¼
32 ½
26 ½
80
240
480
2.5
C3V3-25-3T5
C3V3-25-5T5
51 ¾
41
26 ½
92
240
480
3
C3V3-30-3T5
C3V3-30-5T5
55 ¾
45
39
96
240
480
4.2
C3V3-42-3T5
C3V3-42-5T5
73 ¾
63
26 ½
120
240
480
5
C3V3-50-3T5
C3V3-50-5T5
85 ⅝
74 ⅞
26 ½
140
 
5" - 150#
48 Watts per sq. inch - Water & Mild Solutions
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
24
C5H6-24-3T5
C5H6-24-5T5
43 ½
30
25
140
240
480
30
C5H6-30-3T5
C5H6-30-5T5
50 ½
37
25
155
240
480
36
C5H6-36-3T5
C5H6-36-5T5
60 ¼
48 ½
25
176
240
480
40
C5H6-40-3T5
C5H6-40-5T5
60 ¼
48 ½
25
176
240
480
50
C5H6-50-3T5
C5H6-50-5T5
73 ⅝
61 ⅞
25
210
240
480
60
C5H6-60-3T5
C5H6-60-5T5
86 ⅝
74 ⅞
25
240
 
5" - 150#
23 Watts per sq. inch - Light wt. oils, caustics, air, gases & mild corrosives
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
12
C5M6-12-3T5
C5M6-12-5T5
43 ½
30
25
140
240
480
15
C5M6-15-3T5
C5M6-15-5T5
48 ¾
37
25
155
240
480
18
C5M6-18-3T5
C5M6-18-5T5
60 ¼
48 ½
25
176
240
480
20
C5M6-20-3T5
C5M6-20-5T5
60 ¼
48 ½
25
176
240
480
25
C5M6-25-3T5
C5M6-25-5T5
73 ⅝
61 ⅞
25
210
240
480
30
C5M6-30-3T5
C5M6-30-5T5
86 ⅝
74 ⅞
25
240
 
5" - 150#
13 Watts per sq. inch - Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
6
C5L6-6-3T5
C5L6-6-5T5
45 ¾
32 ½
25
150
240
480
7.5
C5L6-75-3T5
C5L6-75-5T5
50 ½
37
25
155
240
480
9
C5L6-90-3T5
C5L6-90-5T5
60 ¼
48 ½
25
176
240
480
12.5
C5L6-12-3T5
C5L6-12-5T5
73 ⅝
61 ⅞
25
210
240
480
15
C5L6-15-3T5
C5L6-15-5T5
86 ⅝
74 ⅞
25
240
 
5" - 150#
8 Watts per sq. inch - Heavy oils, #6 & Bunker C fuel oils, corrosive, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
3
C5V6-3-3T5
C5V6-3-5T5
33
22 ½
25
120
240
480
5
C5V6-5-3T5
C5V6-5-5T5
48 ¾
37
25
155
240
480
6
C5V6-6-3T5
C5V6-6-5T5
60 ¼
48 ½
25
176
240
480
8.4
C5V6-8-3T5
C5V6-8-5T5
73 ⅝
61 ⅞
25
210
240
480
10
C5V6-10-3T5
C5V6-10-5T5
86 ⅝
74 ⅞
25
240
 
8" - 150#
48 Watts per sq. inch - Water & Mild Solutions
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
50
C8H18-50-3T5
C8H18-50-5T5
45 ¼
24 ¾
21 ¼
425
240
480
75
C8H18-75-3T5
C8H18-75-5T5
53 ¼
32 ¾
29 ¼
395
240
480
100
C8H18-100-3T5
C8H18-100-5T5
60 ¼
39 ¾
36 ¼
415
240
480
150
C8H18-150-3T5
C8H18-150-5T5
77 ⅜
56 ¾
53 ¼
535
240
480
175
C8H18-175-3T5
C8H18-175-5T5
86 ⅜
65 ¾
62 ¼
625
240
480
200
C8H18-200-3T5
C8H18-200-5T5
96 ⅜
75 ¾
72 ¼
705
 
8" - 150#
23 Watts per sq. inch - Light wt. oils, caustics, air, gases & mild corrosives
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
30
C8M18-30-3T5
C8M18-30-5T5
53 ¼
32 ¾
29 ¼
366
240
480
40
C8M18-40-3T5
C8M18-40-5T5
60 ¼
39 ¾
36 ¼
436
240
480
50
C8M18-50-3T5
C8M18-50-5T5
67 ⅞
47 ¼
43 ¾
500
240
480
60
C8M18-60-3T5
C8M18-60-5T5
77 ⅜
56 ¾
53 ¼
590
240
480
70
C8M18-70-3T5
C8M18-70-5T5
86 ⅜
65 ¾
62 ¼
660
240
480
80
C8M18-80-3T5
C8M18-80-5T5
96 ⅜
75 ¾
72 ¼
750
 
8" - 150#
13 Watts per sq. inch - Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
25
C8L18-25-3T5
C8L18-25-5T5
60 ¼
39 ¾
36 ¼
500
240
480
30
C8L18-30-3T5
C8L18-30-5T5
67 ⅞
47 ¼
43 ¾
565
240
480
37.5
C8L18-37-3T5
C8L18-37-5T5
86 ⅜
65 ¾
62 ¼
725
240
480
44
C8L18-44-3T5
C8L18-44-5T5
96 ⅜
75 ¾
72 ¼
815
240
480
50
C8L18-50-3T5
C8L18-50-5T5
96 ⅜
75 ¾
72 ¼
815
 
8" - 150#
8 Watts per sq. inch - Heavy oils, #6 & Bunker C fuel oils, corrosive, air & gases
Volts
3-Ph.
KW
Cat. No.
A
B
C
Wt.
(lbs.)
240
480
13.3
C8V18-13-3T5
C8V18-13-5T5
60 ¼
39 ¾
36 ¼
500
240
480
16.7
C8V18-16-3T5
C8V18-16-5T5
67 ⅞
47 ¼
43 ¾
565
240
480
20
C8V18-20-3T5
C8V18-20-5T5
77 ⅜
56 ¾
53 ¼
650
240
480
23
C8V18-23-3T5
C8V18-23-5T5
86 ⅜
65 ¾
62 ¼
725
240
480
27
C8V18-27-3T5
C8V18-27-5T5
96 ⅜
75 ¾
72 ¼
815

Certifications

Our heaters are currently UL recognized, CSA compliant and CE approved. We are ASME and National Board certified for Section VIII Div 1 Pressure Vessel Welding.

Additionally, we have built heaters to Military standards for the Army, Navy, Coast Guard and DCSC. We have designed and built systems to Canadian pressure vessel codes CRN, ABSA & TSSA. We also meet certain NSF, NACE and API standards.

 
C.S.A CERTIFIDIED FILE #LR61119
 
Registered Firm Mark UL RECOGNIZED FILE #L130401
Registered Firm Mark UL RECOGNIZED FILE #L130401
CE CERTIFIED